How to choose model and capacity
Choose based on average daily electricity consumption: a family of three with an average daily power consumption of 15–22kWh is allocated 10kWh; a single-family house with an average daily consumption of 25–35kWh (including charging piles) is allocated 15kWh; a large house with an average daily consumption of 35–50kWh is allocated 20kWh. A more accurate approach is to retrieve the electricity bills of the past 12 months to see how much electricity was actually used at night (when photovoltaics are not generating electricity). It is most economical to allocate according to this number. If the allocation is too large, users will be dissatisfied with the waste; if the allocation is small, the benefits will be discounted.
Simply divided by capacity and use: portable 0.3–2.2kWh, can be moved with a handle, used outdoors and for emergencies; household 5–30kWh, fixed installation, used with photovoltaics; industrial and commercial 100kWh and above, in the form of cabinets or containers, used for enterprise cost reduction and grid-side applications. The battery cells and BMS platforms of the three are the same, but the structural design, heat dissipation scheme and safety standards are completely different.
C is the charge and discharge rate, 1C means full charge or discharge in 1 hour. 0.5C means that a 100kWh battery has a maximum power of 50kW and is discharged in 2 hours. For industrial and commercial peak shaving and valley filling, 0.5C is generally sufficient (peak periods are usually 2–4 hours); 1C is only required in scenarios that require quick response to power grid frequency regulation or a short discharge window. The higher the magnification, the higher the cost, so don’t blindly chase higher prices.
Liquid cooling is 10–15% more expensive, but the cell temperature difference is controlled within 3°C (air cooling 5–8°C), has a longer life, higher energy density, and takes up less space. Judgment criteria: project scale of more than 500kWh, average daily charging and discharging of two times, ambient temperature above 35°C for a long time, land shortage - if any two suggestions are met, liquid cooling should be selected. Household and small-capacity industrial and commercial air cooling is more cost-effective.
Mainly look at three factors: peak-to-valley price difference, transformer capacity and power consumption curve. If the price difference is above 0.7 yuan, the economics are significant, but if it is below 0.4 yuan, be cautious; the transformer capacity should leave room for peak clipping; the power consumption curve should preferably have obvious peak and valley characteristics. Provide electricity consumption data in the past 12 months, and we can do a free calculation, including installable capacity, annual revenue and payback period. We will tell you directly if the project cannot be settled.
Technology & Performance
Depends on test conditions. HYSPERIX portable EP series maintains more than 80% capacity after 3000-3500 cycles at 25℃, 0.5C, 80% discharge depth; household EH series 6000 times; industrial and commercial EC series uses 314Ah large battery cells, which can reach 8000-10000 times. Assuming that a household charges and discharges once a day, 6,000 times is equivalent to more than 16 years. Actual life is affected by temperature, rate and depth of discharge.
Three reasons: safety — LFP thermal runaway temperature is ~270℃, no fire on nail penetration or crush; life — typically 2–3× the cycles of NMC; cost — no cobalt or nickel, so prices are more stable. Downsides are slightly lower energy density and poorer low-temperature performance, but for stationary storage where weight doesn't matter, these have little impact.
BMS (battery management system) is the brain of the battery, responsible for monitoring cell voltage, temperature, current, and performing equalization, protection, SOC estimation, and communication. BMS level directly determines battery life and safety. We develop our own BMS, the SOC estimation error is controlled within 3%, it supports both passive balancing and active balancing, and the algorithm can be upgraded remotely.
Discharge is supported from -20℃ to -30℃, but the charging lower limit is usually 0℃. The BMS automatically cuts the charge circuit at low temperatures to protect the cells. In cold regions, opt for a low-temperature self-heating module that preheats before charging at -20℃, or install the unit in an insulated indoor space.
System efficiency refers to the round trip efficiency (RTE): charging 100kWh of electricity, it can discharge 92kWh and consume 8kWh. Losses come from PCS conversion, battery internal resistance heating, and auxiliary power consumption (air conditioning, BMS, lighting). When calculating the income of industrial and commercial projects, this number directly affects the arbitrage space, so the actual measured value must be used instead of the theoretical value.
Most can. The household EH series communicates with the inverter through RS485 or CAN, and has been adapted to mainstream brands. Please inform the inverter model before placing an order, and we will check the protocol compatibility first. Unpopular brands can run in "no communication" mode (SOC is judged by voltage), with a slight loss of functionality but usable. We have built-in PCS for industrial and commercial projects, and can also connect to third-party PCS.
Pricing, MOQ & Customization
Prices vary with cell market conditions, configuration scale and customization, so public list prices can mislead. Provide your application, required capacity and target market and we'll issue a complete tiered quote. Generally, larger capacity means lower unit cost — C&I projects above 100kWh have a clearly lower per-Wh price than small residential systems.
Portable standard models MOQ 200 units, residential 50 units, C&I negotiable even for a single unit. We accept small trial orders so you can test the market. Trial pricing differs from volume pricing, but we won't inflate the barrier.
Yes. Appearance layer: body color, silk screen logo, nameplate, color box, manual multi-language typesetting, App and cloud branding. Functional layer: interface configuration, screen display content, BMS policy parameters, communication protocol. The minimum order quantity for structural mold modification projects is 1,000 units, and the mold fee is additional. After signing the brand authorization letter, your appearance plan will not be provided to third parties.
Standard terms for new customers are 30% deposit + 70% against B/L copy, with T/T and L/C supported. Long-term customers with good standing can apply for monthly terms, with limits and duration negotiated. Sample orders generally require full prepayment.
Yes — a regional agency system with three tiers by annual purchase volume: regular distributor, regional agent and exclusive agent, each with its own pricing and support. We use project registration: once you register a project, other channels won't quote on it, avoiding same-region price conflicts. Distributors can request sample discounts, marketing kits and technical training.
Lead Time, Shipping, Installation & After-Sales
Portable standard models 15–20 days, residential standard 20–25 days, C&I cabinets 45–60 days, containerized 60–90 days. Custom projects depend on development complexity; samples typically 15–25 days. Peak season (Sep–Dec) may extend lead times — please plan ahead.
We provide UN38.3 test reports, sea/air transport assessments, MSDS, packing list, commercial invoice and certificate of origin (FORM E / CO available). Lithium batteries are Class 9 dangerous goods — we'll arrange a qualified forwarder and send the dangerous goods packaging certificate and declaration documents to you in advance for review.
We don't provide on-site overseas installation directly — that's done by local licensed electricians or solar installers. We supply English installation manuals, wiring diagrams, wall-mount templates, commissioning videos and remote video guidance. Volume partners can request on-site technical training or have an engineer travel to your market for first-install guidance.
Portable and residential series 5 years; residential EH series 10 years or 6,000 cycles; C&I 10 years or by cycle count, whichever comes first. Non-man-made damage is repaired or replaced free within warranty. We keep spare parts stock for overseas customers — spares ship first, faulty units returned later. Remote technical issues are answered within 24 hours.
Yes. Our Huizhou Boluo base is open — sign an NDA to book an on-site visit, or arrange a live line audit. We suggest booking 3–5 business days ahead; we'll arrange technical staff to walk you through and prepare the product samples you're interested in.